Eaton 9140 (7.5 кВА — 10 кВА)


Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 317

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 318

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 319

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 317

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 318

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 319
Очистить
Предзаказ
Сравнить

Описание

Eaton 9140, Powerware 9140 7.5 и 10 кВА PW9140, PW 9140

Расшифровка заводских (part) номеров ИБП Eaton 9140 серия Powerware

Стоечные ИБП Eaton 9140 7.5 и 10 кВА (серия Powerware) имеют следующие интересные для своего класса особенности:

  • Небольшая высота 6U
  • Каждый ИБП может переключаться между 3ф или 1ф (входом )/1ф выходом тумблером
  • ИБП имеет возможность замены силового модуля «в горячем режиме» — при изъятии силового модуля, ИБП переводит нагрузку на байпас, находящийся в корпусе ИБП
  • Возможность «горячей замены батарей»
  • Выскоая активная мощность:  ИБП при 10 кВА может выдать 8 кВт активной мощности
  • Два независмых входа (Вход байпаса и основной вход)  для увеличения надежности
  • Совместим с блэйд-серверами имеющих стандартные IEC разъемы, вид «сзади»:

ИБП могут быть укомплектованы распред устройствами для стоек  Eaton ePDU

Основная задача ИБП Eaton 9140: Основная задача предлагаемого ИБП с двойным преобразованием напряжения структуры On-line — 100% защита Вашей нагрузки от практически всех существующих помех в электросети: Импульсных высоковольтных бросков, Выбросов напряжения, его длительного падения, Кратковременного повышения/понижения напряжения, нестабильности формы, интерференции, полного отключения электропитания.

Назначение ИБП Powerware 9140 ИБП этой серии предназначены для защиты нагрузки в 19’ стойке (стоечных серверов, концентраторов, маршрутизаторов). ИБП может использоваться для защиты практически любого оборудования с повышенными требованиями к качеству электропитания в самых сложных условиях эксплуатации

Структура On-Line: ИБП работают в режиме On-Line с двойным преобразованием. Это означает, что источник преобразует 100% поступающего к нему на вход переменного напряжения в постоянное, а затем выполняет обратное преобразование. При этом ИБП не пытается подкорректировать входное напряжение, а сам формирует синусоиду заданного качества.Принцип стабилизации заключается в том, что при первом преобразовании (AC->DC) стабильное постоянное DC напряжение можно получить из очень плохого внешнего AC переменного напряжения (плохой формы, повышенного, пониженного и т.д.), а при втором преобразовании (DC->AC) переменное напряжение ИБП формирует сам.

Уникальная технология управления батареями — ABM (Advanced Battery Management) Аккумуляторные батареи часто составляет весомую часть от стоимости ИБП, поэтому продление их жизни серьезно удешевляет эксплутационную стоимость системы бесперебойного питания.

Описание русский

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 317

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 318

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 319

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 317

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 318

Warning: A non-numeric value encountered in /home/u107878/etd-sru/www/wp-content/plugins/woocommerce/includes/class-wc-product-variable.php on line 319
МодельEaton 9140 10 кВА
Мощность10 кВА/ 8 кВт
Однофазный вход220–240 В
Трехфазный вход380/220 В, 400/230 В, 415/240 В
Однофазный вход174–288 В (для 220–240В)
Трехфазный вход301–499 В / 174–288 В
Рабочая частота45–55 Гц
Входной коэффициент мощности> 0.99
КНИ потребляемого от сети тока<5%
Однофазный выход220 В / 230 В / 240 В выбирается пользователем
Регулировка выходного напряжения+/- 2% в статическом режиме, +/- 10% в динамическом режиме
КПД>90%
Тип батарей12В,5 Ач, герметичные, свинцово-кислотные, необслуживаемые
Замена батарей«Горячая замена» батарейных модулей
Зарядное устройствоТок 2.5A, до 4 дополнительных батарейных модулей
Запуск от батарейПозволяет включить ИБП без внешнего питания
ПерегрузкаНагрузка до 110% - работа на байпасе, при нагрузке от 111 до 130% работа на байпасе в течение 60 сек
ЖК дисплейЖК дисплей с подсветкой
Светодиодные индикаторы(4) индикатора для индикации режима работы и сообщений
Коммуникационные порты USB, RS-232 (последовательный),порт аварийного отключения REPO
Коммуникационный слотX-слот
Рабочая температура0°C - 40°C
Относительная влажность0–95% конденсат недопустим
Уровень шума на расст 1.5 м<55 дБ
МодельEaton 9140 7.5 кВА
Мощность7.5 кВА/ 6 кВт
Однофазный вход220–240 В
Трехфазный вход380/220 В, 400/230 В, 415/240 В
Однофазный вход174–288 В (для 220–240В)
Трехфазный вход301–499 В / 174–288 В
Рабочая частота45–55 Гц
Входной коэффициент мощности> 0.99
КНИ потребляемого от сети тока<5%
Однофазный выход220 В / 230 В / 240 В выбирается пользователем
Регулировка выходного напряжения+/- 2% в статическом режиме, +/- 10% в динамическом режиме
КПД>90%
Тип батарей12В,5 Ач, герметичные, свинцово-кислотные, необслуживаемые
Замена батарей«Горячая замена» батарейных модулей
Зарядное устройствоТок 2.5A, до 4 дополнительных батарейных модулей
Запуск от батарейПозволяет включить ИБП без внешнего питания
ПерегрузкаНагрузка до 110% - работа на байпасе, при нагрузке от 111 до 130% работа на байпасе в течение 60 сек
ЖК дисплейЖК дисплей с подсветкой
Светодиодные индикаторы(4) индикатора для индикации режима работы и сообщений
Коммуникационные портыUSB, RS-232 (последовательный),порт аварийного отключения REPO
Коммуникационный слотX-слот
Рабочая температура0°C - 40°C
Относительная влажность0–95% конденсат недопустим
Уровень шума на расст 1.5 м<55 дБ